CAME Capacitors
They don’t often fail, the symptom is weak starting torque. For spare parts please refer to the sales team for advice. Fitting on site & basic tools required.
As a general rule of thumb, electric motor start capacitors can be replaced with a micro-farad or µF or mfd rating equal to or up to 20% higher µF than the original capacitor serving the motor. On the replacement capacitor the voltage rating must be equal to or greater than the original.
SERIES | MOTOR | VALUE (µF) |
AMI | A180 | 9 |
ATI | A3000 | 10 |
A5000 | 10 | |
AXO | AX302304 | 8 |
AX502304 | 8 | |
AX71230 | 8 | |
BK | BK800 | 22 |
BK1200 | 25 | |
BK1200P | 31.5 | |
BK1800 | 31.5 | |
BK2200 | 35 | |
BKS | BKS18ALS | 31.5 |
BX | BX10 | 20 |
BX74 | 12 | |
BX78 | 20 | |
BX246 | 20 | |
BX-A | BX-A | 20 |
BX-B | 20 | |
CLOK | CLOK 3 | 10 |
CLOK 5 | 10 | |
CAT | CAT X | 20 |
FAST | F7000 | 10 |
F7001 | 10 | |
FERNI | F1000 | 10 |
F1100 | 10 | |
FROG | FROG A | 16 |
FROG AE | 16 | |
FROG AL | 12 | |
FROG AV | 20 | |
GARD | G4041 | 16 |
G2081 | 35 | |
G2500 | 6 | |
KRONO | KR300 | 8 |
KR310 | 8 | |
KR500 | 8 | |
KR510 | 8 | |
ZBY | ZBY15 | 20 |