LOOP CONTROLLER
Download SMA PDF
SMA
CAME 009SMA Magnetic Loop Detector Single Channel provides single-channel detection for either automatic exit, safety loop or presence. CAME 009SMA Magnetic Loop Detector Single Channel comes with a 1 Years CAME Manufacturers Warranty.
- Door & Gate: The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-active condition.
- Barrier: The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-active condition.
- Quiescent Current: The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
Voltage: 24 VAC -20% to +10%, max. 2 VA; 24 VDC -10% to +20%, max. 1.5 W
Loop inductance: max. 20 to 1000 µH, ideally 80 to 300 µH
Loop resistance: < 8 Ohm with connection wire
Output relay (loop): max. 240 VAC; 2 A / 30 VDC; 1 A; AC-1
Output relay (alarm): max. 40 VACDC; 0.3 A; AC-1
Dimensions: 22.5 x 94 x 88 mm (B x H x T)
Housing mounting: Direct DIN rail mounting
Operating temperature: -20°C to +60°C